The E110 is an intrinsically safe portable gas detector capable of continuous concentration monitoring for combustible gases, toxic gases and oxygen. It is applicable to explosion-risk zones, toxic gas leakage rescue operations, underground pipelines...
Quote NowThe E110 is an intrinsically safe portable gas detector capable of continuous concentration monitoring for combustible gases, toxic gases and oxygen. It is applicable to explosion-risk zones, toxic gas leakage rescue operations, underground pipelines and other sites, effectively protecting personnel life safety and preventing damage to production equipment.
The detector housing is constructed from high-strength engineering plastic combined with composite anti-slip rubber, featuring high mechanical strength, comfortable grip, as well as water and dust resistance.
Advanced ultra-low power MCU
Wide-view graphic LCD display
Self-check function for combustible gas sensor failure
Low battery alarm
Real-time clock display
Auto-calibration function to minimize measurement error
Audible, visual and vibration alarm indicators
Multi-level alarms including low alarm, high alarm, TWA, STEL, over-range and low battery
Optional functions: parameter configuration, log storage & data export
Power-on self-test (self-diagnosis & fault recovery)
Password management to prevent misoperation
ATEX & IECEx certified
Designed for locations prone to flammable and toxic gas leakage, effectively safeguarding the life safety of on-site staff.
| Item | Specification |
| Detection Method | Natural diffusion sampling |
| Sensor Types | Electrochemical (toxic gas & O₂ sensors), NDIR sensors, PID sensors |
| Display Deviation | CO: Absolute deviation ±5 ppm, Relative deviation ±10%; H₂S: Absolute deviation ±2 ppm, Relative deviation ±10%; O₂: ±2% F.S; Other gases: ±5% F.S |
| Indication Method | LCD screen for real-time data & system status; Audible, visual and vibration indicators for alarms, faults and low battery |
| Communication Interface | USB cable (optional) |
| Operating Environment | Temp: -20℃ ~ +55℃; Humidity: <95% RH (non-condensing); Air pressure: 90kPa ~ 110kPa |
| Power Supply | Rechargeable lithium battery DC 3.7V (Model 604050) |
| Operating Duration | ≥8 hours continuous operation (fully charged, @20℃, no alarm triggered) |
| Charging Environment | Temp: 0℃ ~ 45℃; Humidity: <95% RH (non-condensing); Air pressure: 90kPa ~ 110kPa |
| Sensor Service Life | 2 years |
| Ingress Protection | IP66 / IP67 |
| Intrinsic Safety Rating | Equipped with NDIR sensor: Ex ia op is IIC T4 GaOther sensor types: Ex ia IIC T4 Ga |
| Certificates | IECEx CSA 25.0094X; CSANe 25ATEX1234X |
| Dimensions | 97 mm × 53 mm × 22.5 mm |
| Weight | Approx. 115 g |
| Optional Functions | Parameter configuration, data logging & data export |