Turbidity Tester

Turbidity Tester

photoelectric turbidimeter measures the light scattering degree generated by insoluble particulate matter suspended in water or transparent liquid, and quantitatively characterizes the content of suspended particles.

Quote Now

Introduction

photoelectric turbidimeter measures the light scattering degree generated by insoluble particulate matter suspended in water or transparent liquid, and quantitatively characterizes the content of suspended particles. The instrument is calibrated with Formazine turbidity standard solution specified in international standard ISO7027, and NTU is adopted as turbidity unit. It is widely used for turbidity measurement in power plants, waterworks, domestic sewage treatment plants, beverage factories, environmental protection departments, industrial water, wine-making, pharmaceutical industry, epidemic prevention institutions, hospitals and other facilities. It can give early warning of pollution incidents and provide reliable data support for environmental management authorities.

Features

Color compensation function to compensate scattered light filtered by optical lens

Special anti-bubble device on sensor to effectively avoid air bubble interference

Chinese menu display

Relay contact output & independent 4~20mA transmission output

Microprocessor-based digital program controller

Large-size backlit LCD display

Application

It is widely used for turbidity measurement in power plants, waterworks, domestic sewage treatment plants, beverage factories, environmental protection departments, industrial water, wine-making, pharmaceutical industry, epidemic prevention institutions, hospitals and other facilities.

Specifications

Item Specifications
Application Scope Suitable for wastewater with turbidity ranging from 0~2000NTU
Test Method 90° Light Scattering / Laser Method
Measuring Range 0-10 NTU, 0-100NTU, 0-500NTU, 0-2000NTU (Expandable)
Lower Detection Limit 0.01
Resolution 0.01
Accuracy ±5% or ±0.1 NTU (whichever is larger)
Repeatability 5% or ±0.1 NTU (whichever is larger)
Zero Drift ±0.2 NTU
Span Drift ±10%
Calibration Cycle Manual calibration configurable according to actual water samples
Maintenance Cycle Maintenance interval ≥ 1 month, about 20 minutes each time
Signal Cable 10M as standard, extendable
Self-check Protection Fault data can be stored after power-on, abnormal status or power recovery
Output Interface 1 channel RS232 digital output, 1 channel 4-20mA analog output (2 channels expandable), 2 relay switch outputs
Working Environment Recommended temperature: 5~28℃, Humidity ≤90% (non-condensing)
Power Supply & Power Consumption AC220V±10%, 50Hz, 10W
Dimension 270*210*100(mm) or 150*140*117(mm)
 
 